Your ACTIDYN lab centrifuges are high performance, high precision centrifuges allowing you to study the most advanced and varied subjects, such as:
Your Unit Under Test (UUT) can vary in weight from a few grams to many tons, applied accelerations can reach 20,000 g, your chosen giration radius can exceed 10 m or be as small as 0.1m, and acceleration accuracy can range from 10-2 to 10-6.
The DD denomination indicates that your machine has a “Direct Drive” mechanism as opposed to a belt-driven mechanism. A Direct Drive eliminates de facto certain vibratory noise as well as the use of belts. Performances are significantly enhanced and maintenance of the driving system is virtually eliminated.
Here is a brief overview of the characteristics of your machines:
| Parameter | C10-C12 / DD | C15 / C15-DD | C18-DD | C40 / C40-DD | C58 / C58-DD | C68 | C70-2-DD | V67 |
|---|---|---|---|---|---|---|---|---|
| Radius (m) | 0.4 / 0.5 | 0.9 / 0.9 | 0.4 | 1.8 | 3.1 / 0.9 | 6.0 | 4.0 | 4.0 |
| Payload (Kg) | 20 | 20 / 20 | 10 | 20 | 50 | 500 | 40 | 120 |
| Maximum Acceleration (g) | 50 | 25 / 25 | 200 | 100 | 50 | 80 | 15 | 80 |
| Acceleration Accuracy (ppm) | 200 / 20 | 300 / 30 | 10 | 200 / 2 | 2000 / 200 | 2500 | 10 | 1200 |